All checks were successful
continuous-integration/drone/push Build is passing
488 lines
18 KiB
Markdown
488 lines
18 KiB
Markdown
# Inverter GUI
|
|
|
|
[Repository](https://git.coadcorp.com/nathan/invertergui) | [Container Image](https://registry.coadcorp.com/nathan/invertergui)
|
|
|
|
The invertergui allows the monitoring of a [Victron Multiplus](https://www.victronenergy.com/inverters-chargers/multiplus-12v-24v-48v-800va-3kva) via the [MK3/MK2 USB](https://www.victronenergy.com/accessories/interface-mk3-usb) or the MK2 RS232.
|
|
|
|
The [`registry.coadcorp.com/nathan/invertergui`](https://registry.coadcorp.com/nathan/invertergui) container image is a build of this repository.
|
|
|
|
## Acknowledgements
|
|
|
|
This project is based on the original open source `invertergui` project by Hendrik van Wyk and contributors:
|
|
|
|
- Original repository: https://github.com/diebietse/invertergui
|
|
|
|
## Demo
|
|
|
|

|
|
|
|
## Quick Start
|
|
|
|
```console
|
|
docker run --name invertergui --device /dev/ttyUSB0:/dev/ttyUSB0 -p 8080:8080 registry.coadcorp.com/nathan/invertergui:latest
|
|
```
|
|
|
|
## Requirements
|
|
|
|
This project makes use of [Go Modules](https://github.com/golang/go/wiki/Modules). The minimum supported version for Go is 1.22
|
|
|
|
## Getting started
|
|
|
|
```bash
|
|
Usage:
|
|
invertergui [OPTIONS]
|
|
|
|
Application Options:
|
|
--address= The IP/DNS and port of the machine that the application is running on. (default: :8080) [$ADDRESS]
|
|
--read_only Disable all write operations and run in monitoring-only mode. [$READ_ONLY]
|
|
--data.source= Set the source of data for the inverter gui. "serial", "tcp" or "mock" (default: serial) [$DATA_SOURCE]
|
|
--data.host= Host to connect when source is set to tcp. (default: localhost:8139) [$DATA_HOST]
|
|
--data.device= TTY device to use when source is set to serial. (default: /dev/ttyUSB0) [$DATA_DEVICE]
|
|
--cli.enabled Enable CLI output. [$CLI_ENABLED]
|
|
--mqtt.enabled Enable MQTT publishing. [$MQTT_ENABLED]
|
|
--mqtt.broker= Set the host port and scheme of the MQTT broker. (default: tcp://localhost:1883) [$MQTT_BROKER]
|
|
--mqtt.client_id= Set the client ID for the MQTT connection. (default: inverter-gui) [$MQTT_CLIENT_ID]
|
|
--mqtt.topic= Set the MQTT topic updates published to. (default: invertergui/updates) [$MQTT_TOPIC]
|
|
--mqtt.command_topic= Set the MQTT topic that receives write commands for Victron settings/RAM variables. (default: invertergui/settings/set) [$MQTT_COMMAND_TOPIC]
|
|
--mqtt.status_topic= Set the MQTT topic where write command status updates are published. (default: invertergui/settings/status) [$MQTT_STATUS_TOPIC]
|
|
--mqtt.ha.enabled Enable Home Assistant MQTT discovery integration. [$MQTT_HA_ENABLED]
|
|
--mqtt.ha.discovery_prefix= Set Home Assistant MQTT discovery prefix. (default: homeassistant) [$MQTT_HA_DISCOVERY_PREFIX]
|
|
--mqtt.ha.node_id= Set Home Assistant node ID used for discovery topics and unique IDs. (default: invertergui) [$MQTT_HA_NODE_ID]
|
|
--mqtt.ha.device_name= Set Home Assistant device display name. (default: Victron Inverter) [$MQTT_HA_DEVICE_NAME]
|
|
--mqtt.username= Set the MQTT username [$MQTT_USERNAME]
|
|
--mqtt.password= Set the MQTT password [$MQTT_PASSWORD]
|
|
--mqtt.password-file= Path to a file containing the MQTT password [$MQTT_PASSWORD_FILE]
|
|
--loglevel= The log level to generate logs at. ("panic", "fatal", "error", "warn", "info", "debug", "trace") (default: info) [$LOGLEVEL]
|
|
|
|
Help Options:
|
|
-h, --help Show this help message
|
|
```
|
|
|
|
### Read-Only Mode
|
|
|
|
Set `READ_ONLY=true` (or `--read_only`) to disable all write operations.
|
|
When read-only mode is enabled, the app still monitors and publishes telemetry, but it will not send commands to the Victron device.
|
|
|
|
This affects:
|
|
|
|
- MQTT command handling (`--mqtt.command_topic` commands are ignored)
|
|
- Web UI control actions (`POST /api/remote-panel/state` and `POST /api/remote-panel/standby`)
|
|
|
|
Example `docker-compose.yml` snippet:
|
|
|
|
```yaml
|
|
services:
|
|
invertergui:
|
|
image: registry.coadcorp.com/nathan/invertergui:latest
|
|
environment:
|
|
READ_ONLY: "true"
|
|
```
|
|
|
|
## Port 8080
|
|
|
|
The default HTTP server port is hosted on port 8080. This exposes the HTTP server that hosts the:
|
|
|
|
- Web GUI
|
|
- Munin Plugin
|
|
- Prometheus Monitor
|
|
|
|
### Web GUI
|
|
|
|
The GUI location is at the root (http://localhost:8080/) of the HTTP server.
|
|
|
|
Example output:
|
|
|
|
```
|
|
Date: Mon, 17 Dec 2018 18:14:51 +0000
|
|
LEDs:
|
|
Mains
|
|
Float
|
|
Output Current: 1.580 A
|
|
Output Voltage: 227.830 V
|
|
Output Frequency: 50.026 Hz
|
|
Output Power: 359.971 VA
|
|
Input Current: 1.750 A
|
|
Input Voltage: 227.830 V
|
|
Input Frequency: 50.103 Hz
|
|
Input Power: 398.703 VA
|
|
Input - Output Power: 38.731 VA
|
|
|
|
Battery Current: -0.050 A
|
|
Battery Voltage: 13.170 V
|
|
Battery Power: -0.659 W
|
|
Battery Charge: 100.000 %
|
|
```
|
|
|
|
The web UI also includes a **Remote Panel Control** section for:
|
|
|
|
- Remote Panel Mode (`on`, `off`, `charger_only`, `inverter_only`)
|
|
- Remote Panel Current Limit (AC input current limit in amps)
|
|
- Remote Panel Standby (prevent sleep while turned off)
|
|
|
|
The combined mode + current limit action maps to the same behavior as
|
|
`set_remote_panel_state` in `victron-mk3`.
|
|
|
|
The backing HTTP API endpoints are:
|
|
|
|
- `GET/POST /api/remote-panel/state`
|
|
- `GET/POST /api/remote-panel/standby`
|
|
|
|
### Munin
|
|
|
|
The Munin plugin location is at /munin (http://localhost:8080/munin).
|
|
|
|
Example output:
|
|
|
|
```
|
|
multigraph in_batvolt
|
|
volt.value 13.154
|
|
multigraph in_batcharge
|
|
charge.value 100.000
|
|
multigraph in_batcurrent
|
|
current.value -0.092
|
|
multigraph in_batpower
|
|
power.value -1.209
|
|
multigraph in_mainscurrent
|
|
currentin.value 1.860
|
|
currentout.value 1.676
|
|
multigraph in_mainsvoltage
|
|
voltagein.value 225.786
|
|
voltageout.value 225.786
|
|
multigraph in_mainspower
|
|
powerin.value 419.945
|
|
powerout.value 378.372
|
|
multigraph in_mainsfreq
|
|
freqin.value 50.361
|
|
freqout.value 50.026
|
|
```
|
|
|
|
### Prometheus
|
|
|
|
The Prometheus endpoint is at the default /metrics path (http://localhost:8080/metrics).
|
|
|
|
Sample Prometheus yaml entry:
|
|
|
|
```yml
|
|
- job_name: "victron"
|
|
static_configs:
|
|
- targets: ["localhost:8080"]
|
|
```
|
|
|
|
The metrics that are tracked:
|
|
|
|
```
|
|
# HELP battery_charge_percentage Remaining battery charge.
|
|
# TYPE battery_charge_percentage gauge
|
|
battery_charge_percentage 100
|
|
# HELP battery_current_a Battery current.
|
|
# TYPE battery_current_a gauge
|
|
battery_current_a -0.06
|
|
# HELP battery_power_w Battery power.
|
|
# TYPE battery_power_w gauge
|
|
battery_power_w -0.7896
|
|
# HELP battery_voltage_v Voltage of the battery.
|
|
# TYPE battery_voltage_v gauge
|
|
battery_voltage_v 13.16
|
|
# HELP go_gc_duration_seconds A summary of the GC invocation durations.
|
|
# TYPE go_gc_duration_seconds summary
|
|
go_gc_duration_seconds{quantile="0"} 5.3183e-05
|
|
go_gc_duration_seconds{quantile="0.25"} 0.000116
|
|
go_gc_duration_seconds{quantile="0.5"} 0.000156305
|
|
go_gc_duration_seconds{quantile="0.75"} 0.000313721
|
|
go_gc_duration_seconds{quantile="1"} 0.044886879
|
|
go_gc_duration_seconds_sum 0.394171418
|
|
go_gc_duration_seconds_count 58
|
|
# HELP go_goroutines Number of goroutines that currently exist.
|
|
# TYPE go_goroutines gauge
|
|
go_goroutines 8
|
|
# HELP go_info Information about the Go environment.
|
|
# TYPE go_info gauge
|
|
go_info{version="go1.11.3"} 1
|
|
# HELP go_memstats_alloc_bytes Number of bytes allocated and still in use.
|
|
# TYPE go_memstats_alloc_bytes gauge
|
|
go_memstats_alloc_bytes 3.21496e+06
|
|
# HELP go_memstats_alloc_bytes_total Total number of bytes allocated, even if freed.
|
|
# TYPE go_memstats_alloc_bytes_total counter
|
|
go_memstats_alloc_bytes_total 1.7361072e+08
|
|
# HELP go_memstats_buck_hash_sys_bytes Number of bytes used by the profiling bucket hash table.
|
|
# TYPE go_memstats_buck_hash_sys_bytes gauge
|
|
go_memstats_buck_hash_sys_bytes 1.451092e+06
|
|
# HELP go_memstats_frees_total Total number of frees.
|
|
# TYPE go_memstats_frees_total counter
|
|
go_memstats_frees_total 263807
|
|
# HELP go_memstats_gc_cpu_fraction The fraction of this program's available CPU time used by the GC since the program started.
|
|
# TYPE go_memstats_gc_cpu_fraction gauge
|
|
go_memstats_gc_cpu_fraction 0.00018297252897512647
|
|
# HELP go_memstats_gc_sys_bytes Number of bytes used for garbage collection system metadata.
|
|
# TYPE go_memstats_gc_sys_bytes gauge
|
|
go_memstats_gc_sys_bytes 2.37568e+06
|
|
# HELP go_memstats_heap_alloc_bytes Number of heap bytes allocated and still in use.
|
|
# TYPE go_memstats_heap_alloc_bytes gauge
|
|
go_memstats_heap_alloc_bytes 3.21496e+06
|
|
# HELP go_memstats_heap_idle_bytes Number of heap bytes waiting to be used.
|
|
# TYPE go_memstats_heap_idle_bytes gauge
|
|
go_memstats_heap_idle_bytes 6.2537728e+07
|
|
# HELP go_memstats_heap_inuse_bytes Number of heap bytes that are in use.
|
|
# TYPE go_memstats_heap_inuse_bytes gauge
|
|
go_memstats_heap_inuse_bytes 3.981312e+06
|
|
# HELP go_memstats_heap_objects Number of allocated objects.
|
|
# TYPE go_memstats_heap_objects gauge
|
|
go_memstats_heap_objects 5588
|
|
# HELP go_memstats_heap_released_bytes Number of heap bytes released to OS.
|
|
# TYPE go_memstats_heap_released_bytes gauge
|
|
go_memstats_heap_released_bytes 0
|
|
# HELP go_memstats_heap_sys_bytes Number of heap bytes obtained from system.
|
|
# TYPE go_memstats_heap_sys_bytes gauge
|
|
go_memstats_heap_sys_bytes 6.651904e+07
|
|
# HELP go_memstats_last_gc_time_seconds Number of seconds since 1970 of last garbage collection.
|
|
# TYPE go_memstats_last_gc_time_seconds gauge
|
|
go_memstats_last_gc_time_seconds 1.5450709952576678e+09
|
|
# HELP go_memstats_lookups_total Total number of pointer lookups.
|
|
# TYPE go_memstats_lookups_total counter
|
|
go_memstats_lookups_total 0
|
|
# HELP go_memstats_mallocs_total Total number of mallocs.
|
|
# TYPE go_memstats_mallocs_total counter
|
|
go_memstats_mallocs_total 269395
|
|
# HELP go_memstats_mcache_inuse_bytes Number of bytes in use by mcache structures.
|
|
# TYPE go_memstats_mcache_inuse_bytes gauge
|
|
go_memstats_mcache_inuse_bytes 3456
|
|
# HELP go_memstats_mcache_sys_bytes Number of bytes used for mcache structures obtained from system.
|
|
# TYPE go_memstats_mcache_sys_bytes gauge
|
|
go_memstats_mcache_sys_bytes 16384
|
|
# HELP go_memstats_mspan_inuse_bytes Number of bytes in use by mspan structures.
|
|
# TYPE go_memstats_mspan_inuse_bytes gauge
|
|
go_memstats_mspan_inuse_bytes 27208
|
|
# HELP go_memstats_mspan_sys_bytes Number of bytes used for mspan structures obtained from system.
|
|
# TYPE go_memstats_mspan_sys_bytes gauge
|
|
go_memstats_mspan_sys_bytes 32768
|
|
# HELP go_memstats_next_gc_bytes Number of heap bytes when next garbage collection will take place.
|
|
# TYPE go_memstats_next_gc_bytes gauge
|
|
go_memstats_next_gc_bytes 4.194304e+06
|
|
# HELP go_memstats_other_sys_bytes Number of bytes used for other system allocations.
|
|
# TYPE go_memstats_other_sys_bytes gauge
|
|
go_memstats_other_sys_bytes 775332
|
|
# HELP go_memstats_stack_inuse_bytes Number of bytes in use by the stack allocator.
|
|
# TYPE go_memstats_stack_inuse_bytes gauge
|
|
go_memstats_stack_inuse_bytes 589824
|
|
# HELP go_memstats_stack_sys_bytes Number of bytes obtained from system for stack allocator.
|
|
# TYPE go_memstats_stack_sys_bytes gauge
|
|
go_memstats_stack_sys_bytes 589824
|
|
# HELP go_memstats_sys_bytes Number of bytes obtained from system.
|
|
# TYPE go_memstats_sys_bytes gauge
|
|
go_memstats_sys_bytes 7.176012e+07
|
|
# HELP go_threads Number of OS threads created.
|
|
# TYPE go_threads gauge
|
|
go_threads 10
|
|
# HELP mains_current_in_a Mains current flowing into inverter
|
|
# TYPE mains_current_in_a gauge
|
|
mains_current_in_a 2.17
|
|
# HELP mains_current_out_a Mains current flowing out of inverter
|
|
# TYPE mains_current_out_a gauge
|
|
mains_current_out_a 2
|
|
# HELP mains_freq_in_hz Mains frequency at inverter input
|
|
# TYPE mains_freq_in_hz gauge
|
|
mains_freq_in_hz 50.36082474226804
|
|
# HELP mains_freq_out_hz Mains frequency at inverter output
|
|
# TYPE mains_freq_out_hz gauge
|
|
mains_freq_out_hz 50.153452685421996
|
|
# HELP mains_power_in_va Mains power in
|
|
# TYPE mains_power_in_va gauge
|
|
mains_power_in_va 491.6352
|
|
# HELP mains_power_out_va Mains power out
|
|
# TYPE mains_power_out_va gauge
|
|
mains_power_out_va 453.12
|
|
# HELP mains_voltage_in_v Mains voltage at input of inverter
|
|
# TYPE mains_voltage_in_v gauge
|
|
mains_voltage_in_v 226.56
|
|
# HELP mains_voltage_out_v Mains voltage at output of inverter
|
|
# TYPE mains_voltage_out_v gauge
|
|
mains_voltage_out_v 226.56
|
|
# HELP process_cpu_seconds_total Total user and system CPU time spent in seconds.
|
|
# TYPE process_cpu_seconds_total counter
|
|
process_cpu_seconds_total 39.73
|
|
# HELP process_max_fds Maximum number of open file descriptors.
|
|
# TYPE process_max_fds gauge
|
|
process_max_fds 1.048576e+06
|
|
# HELP process_open_fds Number of open file descriptors.
|
|
# TYPE process_open_fds gauge
|
|
process_open_fds 8
|
|
# HELP process_resident_memory_bytes Resident memory size in bytes.
|
|
# TYPE process_resident_memory_bytes gauge
|
|
process_resident_memory_bytes 1.2742656e+07
|
|
# HELP process_start_time_seconds Start time of the process since unix epoch in seconds.
|
|
# TYPE process_start_time_seconds gauge
|
|
process_start_time_seconds 1.54506833485e+09
|
|
# HELP process_virtual_memory_bytes Virtual memory size in bytes.
|
|
# TYPE process_virtual_memory_bytes gauge
|
|
process_virtual_memory_bytes 1.15101696e+08
|
|
```
|
|
|
|
### MQTT
|
|
|
|
The MQTT client will publish updates to the given broker at the set topic.
|
|
|
|
#### MQTT Configuration Options
|
|
|
|
```bash
|
|
--mqtt.enabled Enable MQTT publishing. [$MQTT_ENABLED]
|
|
--mqtt.broker= Set the host port and scheme of the MQTT broker. (default: tcp://localhost:1883) [$MQTT_BROKER]
|
|
--mqtt.client_id= Set the client ID for the MQTT connection. (default: inverter-gui) [$MQTT_CLIENT_ID]
|
|
--mqtt.topic= Set the MQTT topic updates published to. (default: invertergui/updates) [$MQTT_TOPIC]
|
|
--mqtt.command_topic= Set the MQTT topic that receives write commands for Victron settings/RAM variables. (default: invertergui/settings/set) [$MQTT_COMMAND_TOPIC]
|
|
--mqtt.status_topic= Set the MQTT topic where write command status updates are published. (default: invertergui/settings/status) [$MQTT_STATUS_TOPIC]
|
|
--mqtt.ha.enabled Enable Home Assistant MQTT discovery integration. [$MQTT_HA_ENABLED]
|
|
--mqtt.ha.discovery_prefix= Set Home Assistant MQTT discovery prefix. (default: homeassistant) [$MQTT_HA_DISCOVERY_PREFIX]
|
|
--mqtt.ha.node_id= Set Home Assistant node ID used for discovery topics and unique IDs. (default: invertergui) [$MQTT_HA_NODE_ID]
|
|
--mqtt.ha.device_name= Set Home Assistant device display name. (default: Victron Inverter) [$MQTT_HA_DEVICE_NAME]
|
|
--mqtt.username= Set the MQTT username [$MQTT_USERNAME]
|
|
--mqtt.password= Set the MQTT password [$MQTT_PASSWORD]
|
|
--mqtt.password-file= Path to a file containing the MQTT password [$MQTT_PASSWORD_FILE]
|
|
```
|
|
|
|
Related global option:
|
|
|
|
```bash
|
|
--read_only Disable all write operations and run in monitoring-only mode. [$READ_ONLY]
|
|
```
|
|
|
|
The MQTT client can be enabled by setting the environment variable `MQTT_ENABLED=true` or flag `--mqtt.enabled`.
|
|
All MQTT configuration can be done via flags or as environment variables.
|
|
The URI for the broker can be configured format should be `scheme://host:port`, where "scheme" is one of "tcp", "ssl", or "ws".
|
|
|
|
When `--mqtt.command_topic` is configured, the application subscribes to that topic and accepts JSON write commands.
|
|
The recommended command for inverter control follows the same model used by `victron-mk3`:
|
|
|
|
```json
|
|
{
|
|
"request_id": "optional-correlation-id",
|
|
"kind": "panel_state",
|
|
"switch": "on",
|
|
"current_limit": 16.5
|
|
}
|
|
```
|
|
|
|
`switch` supports `charger_only`, `inverter_only`, `on`, and `off` (or numeric values `1..4`).
|
|
`current_limit` is in amps and optional. If omitted, only the switch state is changed.
|
|
To update only the current limit (while preserving the last known mode), send:
|
|
|
|
```json
|
|
{
|
|
"kind": "panel_state",
|
|
"current_limit": 12.0
|
|
}
|
|
```
|
|
|
|
If no prior mode is known (for example on a fresh broker state), this command is rejected until a mode command is sent once.
|
|
|
|
Standby can be controlled with:
|
|
|
|
```json
|
|
{
|
|
"kind": "standby",
|
|
"standby": true
|
|
}
|
|
```
|
|
|
|
Low-level writes are still supported:
|
|
|
|
```json
|
|
{
|
|
"kind": "setting",
|
|
"id": 15,
|
|
"value": 1
|
|
}
|
|
```
|
|
|
|
`kind` supports `panel_state`, `setting`, and `ram_var` (with aliases for each).
|
|
The result is published to `--mqtt.status_topic` with status `ok` or `error`.
|
|
|
|
### Home Assistant
|
|
|
|
Enable Home Assistant auto-discovery with:
|
|
|
|
```bash
|
|
--mqtt.ha.enabled
|
|
```
|
|
|
|
When enabled, `invertergui` publishes retained discovery payloads and availability under:
|
|
|
|
- `{topic-root}/homeassistant/availability` (`online`/`offline`)
|
|
- `{discovery_prefix}/sensor/{node_id}/.../config`
|
|
- `{discovery_prefix}/binary_sensor/{node_id}/.../config`
|
|
- `{discovery_prefix}/select/{node_id}/remote_panel_mode/config` (if command topic is configured)
|
|
- `{discovery_prefix}/number/{node_id}/remote_panel_current_limit/config` (if command topic is configured)
|
|
- `{discovery_prefix}/switch/{node_id}/remote_panel_standby/config` (if command topic is configured)
|
|
|
|
The discovered entities include battery/input/output sensors, a data-valid diagnostic binary sensor,
|
|
plus remote panel controls for:
|
|
|
|
- `Remote Panel Mode` (`on`, `off`, `charger_only`, `inverter_only`)
|
|
- `Remote Panel Current Limit` (AC input current limit in amps)
|
|
- `Remote Panel Standby` (prevent device sleep while off)
|
|
|
|
The combined mode + current limit behavior is provided through the `panel_state` MQTT command kind,
|
|
which mirrors `victron_mk3.set_remote_panel_state`.
|
|
|
|
## TTY Device
|
|
|
|
The intertergui application makes use of a serial tty device to monitor the Multiplus.
|
|
|
|
Example
|
|
|
|
```
|
|
-dev=/dev/ttyUSB0
|
|
```
|
|
|
|
## Nginx Proxy
|
|
|
|
The following configuration works for Nginx to allow the `invertergui` to be proxied.
|
|
|
|
When using a stand HTTP or HTTPS port to expose the gui:
|
|
|
|
```Ini
|
|
location /invertergui {
|
|
return 302 /invertergui/;
|
|
}
|
|
|
|
location /invertergui/ {
|
|
proxy_pass http://localhost:8080/;
|
|
proxy_set_header Host $host;
|
|
}
|
|
|
|
location /invertergui/ws {
|
|
proxy_pass http://localhost:8080/ws;
|
|
proxy_http_version 1.1;
|
|
proxy_set_header Upgrade $http_upgrade;
|
|
|
|
proxy_set_header Connection "upgrade";
|
|
proxy_read_timeout 86400;
|
|
proxy_set_header Host $host;
|
|
|
|
proxy_set_header Referer $http_referer;
|
|
proxy_set_header X-Forwarded-For $remote_addr;
|
|
proxy_set_header X-Forwarded-Proto $scheme;
|
|
proxy_set_header X-Forwarded-Port $server_port;
|
|
}
|
|
```
|
|
|
|
When using a non-stand HTTP or HTTPS port to expose the gui change the HTTP Host description:
|
|
|
|
```Ini
|
|
proxy_set_header Host $host:$server_port;
|
|
```
|
|
|
|
The last four lines are optional, but is useful when debugging and logging connections:
|
|
|
|
```Ini
|
|
proxy_set_header Referer $http_referer;
|
|
proxy_set_header X-Forwarded-For $remote_addr;
|
|
proxy_set_header X-Forwarded-Proto $scheme;
|
|
proxy_set_header X-Forwarded-Port $server_port;
|
|
```
|
|
|
|
## Grafana
|
|
|
|