package mk2driver
import "time"
type Led int
const (
LedMain Led = iota
LedAbsorption
LedBulk
LedFloat
LedInverter
LedOverload
LedLowBattery
LedTemperature
)
var LedNames = map[Led]string{
LedTemperature: "led_over_temp",
LedLowBattery: "led_bat_low",
LedOverload: "led_overload",
LedInverter: "led_inverter",
LedFloat: "led_float",
LedBulk: "led_bulk",
LedAbsorption: "led_absorb",
LedMain: "led_mains",
}
type LEDstate int
const (
LedOff LEDstate = iota
LedOn
LedBlink
)
var StateNames = map[LEDstate]string{
LedOff: "off",
LedOn: "on",
LedBlink: "blink",
}
type Mk2Info struct {
// Will be marked as false if an error is detected.
Valid bool
Version uint32
BatVoltage float64
// Positive current == charging
// Negative current == discharging
BatCurrent float64
// Input AC parameters
InVoltage float64
InCurrent float64
InFrequency float64
// Output AC parameters
OutVoltage float64
OutCurrent float64
OutFrequency float64
// Charge state 0.0 to 1.0
ChargeState float64
// List LEDs
LEDs map[Led]LEDstate
Errors []error
Timestamp time.Time
}
type Mk2 interface {
C() chan *Mk2Info
Close()
}
type PanelSwitchState byte
const (
// PanelSwitchChargerOnly enables charging only.
PanelSwitchChargerOnly PanelSwitchState = 0x01
// PanelSwitchInverterOnly enables inverter output and disables charging.
PanelSwitchInverterOnly PanelSwitchState = 0x02
// PanelSwitchOn enables both inverter and charger.
PanelSwitchOn PanelSwitchState = 0x03
// PanelSwitchOff disables inverter and charger.
PanelSwitchOff PanelSwitchState = 0x04
)
type SettingsWriter interface {
// WriteRAMVar writes a signed 16-bit value to a RAM variable id.
WriteRAMVar(id uint16, value int16) error
// WriteSetting writes a signed 16-bit value to a setting id.
WriteSetting(id uint16, value int16) error
// SetPanelState sends the MK2 "S" command using a virtual panel switch state.
// If currentLimitA is nil, the command does not update the AC current limit.
SetPanelState(switchState PanelSwitchState, currentLimitA *float64) error
// SetStandby configures the remote panel standby line.
// When enabled, the inverter is prevented from sleeping while switched off.
SetStandby(enabled bool) error
}
type DeviceState byte
const (
// DeviceStateChargerOnly enables charging only.
DeviceStateChargerOnly DeviceState = 0x02
// DeviceStateInverterOnly enables inverter output and disables charging.
DeviceStateInverterOnly DeviceState = 0x03
// DeviceStateOn enables both inverter and charger.
DeviceStateOn DeviceState = 0x04
// DeviceStateOff disables inverter and charger.
DeviceStateOff DeviceState = 0x05
)
var DeviceStateNames = map[DeviceState]string{
DeviceStateChargerOnly: "charger_only",
DeviceStateInverterOnly: "inverter_only",
DeviceStateOn: "on",
DeviceStateOff: "off",
}
type RAMVarInfo struct {
ID uint16
Scale int16
Offset int16
Factor float64
Signed bool
Supported bool
}
// ProtocolControl exposes protocol 3.14 command paths for direct MK2 control.
type ProtocolControl interface {
SettingsWriter
// GetDeviceState returns the current VE.Bus state using command 0x0E.
GetDeviceState() (DeviceState, error)
// SetDeviceState sets the VE.Bus state using command 0x0E.
SetDeviceState(state DeviceState) error
// ReadRAMVarByID reads a RAM variable via command 0x30.
ReadRAMVarByID(id uint16) (int16, error)
// ReadSettingByID reads a setting via command 0x31.
ReadSettingByID(id uint16) (int16, error)
// SelectRAMVar selects a RAM variable for follow-up read-selected/write-selected paths.
SelectRAMVar(id uint16) error
// SelectSetting selects a setting for follow-up read-selected/write-selected paths.
SelectSetting(id uint16) error
// ReadSelected reads the currently selected value via command 0x35.
ReadSelected() (int16, error)
// ReadRAMVarInfo reads RAM variable metadata via command 0x36.
ReadRAMVarInfo(id uint16) (RAMVarInfo, error)
// WriteSettingByID writes a setting via command 0x37.
WriteSettingByID(id uint16, value int16) error
// WriteRAMVarByID writes a RAM variable via command 0x38.
WriteRAMVarByID(id uint16, value int16) error
}