30 KiB
Inverter GUI
The invertergui allows the monitoring of a Victron Multiplus via the MK3/MK2 USB or the MK2 RS232.
The registry.coadcorp.com/nathan/invertergui container image is a build of this repository.
The code has been updated to support more of the protocol published by Victron at https://www.victronenergy.com/upload/documents/Technical-Information-Interfacing-with-VE-Bus-products-MK2-Protocol-3-14.pdf
Acknowledgements
This project is based on the original open source invertergui project by Hendrik van Wyk and contributors:
- Original repository: https://github.com/diebietse/invertergui
- Home Assistant
victron-mk3-hassinspiration: https://github.com/j9brown/victron-mk3-hass
Demo
Quick Start
docker run --name invertergui --device /dev/ttyUSB0:/dev/ttyUSB0 -p 8080:8080 registry.coadcorp.com/nathan/invertergui:latest
Requirements
This project makes use of Go Modules. The minimum supported version for Go is 1.22
Driver API: Metadata + Safe Transactions
The MK2 driver now includes a metadata and transaction safety layer via the
mk2driver.MetadataControl interface:
- Register metadata lookup (
RegisterMetadata,ListRegisterMetadata) - Generic register reads by kind/id (
ReadRegister) - Transactional writes with retry and verify (
WriteRegister)
WriteRegister supports:
ReadBeforeWriteVerifyAfterWrite- configurable retry count and delay
This layer is additive and does not replace existing WriteSetting, WriteRAMVar,
or panel control APIs.
Advanced Control + Orchestration Features
The codebase now includes:
- Full MK2 command-path coverage in driver APIs for:
0x0Edevice state read/write- register read by id (
0x30,0x31) - selected read/write flows (
0x32,0x33,0x34,0x35) - RAM var metadata/info (
0x36) - write-by-id flows (
0x37,0x38)
- Register metadata with
unit,min/max,scale,writable, andsafety_class. - Transaction-safe writes with read-before-write, verify-after-write, retry/backoff, and timeout classes.
- Snapshot/diff/restore register workflows with rollback on partial restore failure.
- Alarm engine with LED/state alarms + command-failure alarms, including debounce and clear behavior.
- Venus-like derived operating state model:
Off,Inverter,Charger,Passthru,Fault. - Historical counters for energy and availability:
energy_in_wh,energy_out_wh- battery charge/discharge Wh
- uptime seconds
- fault count + last fault timestamp
- Multi-device orchestration fields and topics:
device_id,instance_id,phase,phase_group- per-device topics and phase-group fanout topics
- Command arbitration/policy layer:
- single serialized write path
- lockout windows
- source tagging (
ui,mqtt,automation) - max current guardrail + mode rate limit + maintenance/read-only profiles
- Venus-compatible MQTT mode (
N/...+ optionalW/...) for HA/Node-RED/VRM-style workflows. - Guide-style Victron ESS MQTT paths (
settings/0/Settings/CGwacs/*) withvictron/N/...andvictron/W/...prefix compatibility. - Structured diagnostics bundle topics with protocol traces, recent command history, and health score.
Getting started
Usage:
invertergui [OPTIONS]
Application Options:
--address= The IP/DNS and port of the machine that the application is running on. (default: :8080) [$ADDRESS]
--read_only Disable all write operations and run in monitoring-only mode. [$READ_ONLY]
--data.source= Set the source of data for the inverter gui. "serial", "tcp" or "mock" (default: serial) [$DATA_SOURCE]
--data.host= Host to connect when source is set to tcp. (default: localhost:8139) [$DATA_HOST]
--data.device= TTY device to use when source is set to serial. (default: /dev/ttyUSB0) [$DATA_DEVICE]
--cli.enabled Enable CLI output. [$CLI_ENABLED]
--mqtt.enabled Enable MQTT publishing. [$MQTT_ENABLED]
--mqtt.broker= Set the host port and scheme of the MQTT broker. (default: tcp://localhost:1883) [$MQTT_BROKER]
--mqtt.client_id= Set the client ID for the MQTT connection. (default: inverter-gui) [$MQTT_CLIENT_ID]
--mqtt.topic= Set the MQTT topic updates published to. (default: invertergui/updates) [$MQTT_TOPIC]
--mqtt.command_topic= Set the MQTT topic that receives write commands for Victron settings/RAM variables. (default: invertergui/settings/set) [$MQTT_COMMAND_TOPIC]
--mqtt.status_topic= Set the MQTT topic where write command status updates are published. (default: invertergui/settings/status) [$MQTT_STATUS_TOPIC]
--mqtt.device_id= Set logical device ID used for per-device orchestration topics. (default: invertergui) [$MQTT_DEVICE_ID]
--mqtt.history_size= Number of samples retained for rolling history summaries. (default: 120) [$MQTT_HISTORY_SIZE]
--mqtt.instance_id= Device instance ID for multi-device orchestration and Venus compatibility. (default: 0) [$MQTT_INSTANCE_ID]
--mqtt.phase= Electrical phase label for this instance (L1/L2/L3). (default: L1) [$MQTT_PHASE]
--mqtt.phase_group= Grouping key for parallel/3-phase system aggregation topics. (default: default) [$MQTT_PHASE_GROUP]
--mqtt.ha.enabled Enable Home Assistant MQTT discovery integration. [$MQTT_HA_ENABLED]
--mqtt.ha.discovery_prefix= Set Home Assistant MQTT discovery prefix. (default: homeassistant) [$MQTT_HA_DISCOVERY_PREFIX]
--mqtt.ha.node_id= Set Home Assistant node ID used for discovery topics and unique IDs. (default: invertergui) [$MQTT_HA_NODE_ID]
--mqtt.ha.device_name= Set Home Assistant device display name. (default: Victron Inverter) [$MQTT_HA_DEVICE_NAME]
--mqtt.venus.enabled Enable Venus-style MQTT compatibility topics (N/W model). [$MQTT_VENUS_ENABLED]
--mqtt.venus.portal_id= Set Venus portal ID segment used in N/W topics. (default: invertergui) [$MQTT_VENUS_PORTAL_ID]
--mqtt.venus.service= Set Venus service segment used in N/W topics. (default: vebus/257) [$MQTT_VENUS_SERVICE]
--mqtt.venus.subscribe_writes Subscribe to Venus W/... topics and map to MK2 commands. [$MQTT_VENUS_SUBSCRIBE_WRITES]
--mqtt.venus.topic_prefix= Optional topic prefix before Venus N/W topics, e.g. victron. [$MQTT_VENUS_TOPIC_PREFIX]
--mqtt.venus.guide_compat Enable guide-style settings/0/Settings/CGwacs compatibility paths. [$MQTT_VENUS_GUIDE_COMPAT]
--mqtt.username= Set the MQTT username [$MQTT_USERNAME]
--mqtt.password= Set the MQTT password [$MQTT_PASSWORD]
--mqtt.password-file= Path to a file containing the MQTT password [$MQTT_PASSWORD_FILE]
--control.profile= Write policy profile: normal, maintenance, or read_only. (default: normal) [$CONTROL_PROFILE]
--control.max_current_limit= Optional max AC current limit guardrail in amps (0 disables). (default: 0) [$CONTROL_MAX_CURRENT_LIMIT]
--control.mode_change_min_interval= Minimum time between mode changes. (default: 3s) [$CONTROL_MODE_CHANGE_MIN_INTERVAL]
--control.lockout_window= Post-command lockout window for command arbitration. (default: 0s) [$CONTROL_LOCKOUT_WINDOW]
--control.allowed_panel_modes= Comma-separated allowlist of remote panel modes. Supported values: on, off, charger_only, inverter_only. Empty allows all modes. [$CONTROL_ALLOWED_PANEL_MODES]
--loglevel= The log level to generate logs at. ("panic", "fatal", "error", "warn", "info", "debug", "trace") (default: info) [$LOGLEVEL]
Help Options:
-h, --help Show this help message
Read-Only Mode
Set READ_ONLY=true (or --read_only) to disable all write operations.
When read-only mode is enabled, the app still monitors and publishes telemetry, but it will not send commands to the Victron device.
This affects:
- MQTT command handling (
--mqtt.command_topiccommands are ignored) - Web UI control actions (
POST /api/remote-panel/stateandPOST /api/remote-panel/standby)
Remote Panel Mode Allowlist
Set CONTROL_ALLOWED_PANEL_MODES (or --control.allowed_panel_modes) to restrict which
remote panel modes can be selected from Web UI, MQTT, Home Assistant, and Venus-compatible
write paths.
Supported values:
onoffcharger_onlyinverter_only
Use a comma-separated list. Empty means all modes are allowed.
Example:
CONTROL_ALLOWED_PANEL_MODES=off,charger_only
Example docker-compose.yml snippet:
services:
invertergui:
image: registry.coadcorp.com/nathan/invertergui:latest
environment:
READ_ONLY: "true"
CONTROL_ALLOWED_PANEL_MODES: "off,charger_only"
devices:
- "/dev/ttyUSB0:/dev/ttyUSB0"
command: ["--mqtt.enabled", "--mqtt.broker=tcp://192.168.1.1:1883", "--loglevel=info"]
Home Assistant Guide-Style ESS Control
To mimic the Victron community ESS control approach (MQTT N/... state + W/... writes under settings/0/Settings/CGwacs/...):
- Start invertergui with:
MQTT_VENUS_ENABLED=trueMQTT_VENUS_GUIDE_COMPAT=trueMQTT_VENUS_TOPIC_PREFIX=victronMQTT_VENUS_PORTAL_ID=invertergui(or your chosen portal id)
- In Home Assistant:
- Use the included custom integration (
custom_components/victron_mk2_mqtt) which now exposes ESS-style entities and service calls. - Or use
homeassistant/packages/invertergui_mqtt.yaml, which includes guide-style MQTT entities:number.victron_ess_grid_setpointnumber.victron_ess_max_charge_powernumber.victron_ess_max_discharge_powerswitch.victron_ess_optimized_mode
- Use the included custom integration (
Compatibility note:
- MK2/VE.Bus does not expose every Venus ESS feature one-to-one. This project maps ESS-style commands onto available MK2 controls (mode/current-limit/policy-safe behavior) to provide similar Home Assistant control flow.
Port 8080
The default HTTP server port is hosted on port 8080. This exposes the HTTP server that hosts the:
- Web GUI
- Munin Plugin
- Prometheus Monitor
Web GUI
The GUI location is at the root (http://localhost:8080/) of the HTTP server.
Example output:
Date: Mon, 17 Dec 2018 18:14:51 +0000
LEDs:
Mains
Float
Output Current: 1.580 A
Output Voltage: 227.830 V
Output Frequency: 50.026 Hz
Output Power: 359.971 VA
Input Current: 1.750 A
Input Voltage: 227.830 V
Input Frequency: 50.103 Hz
Input Power: 398.703 VA
Input - Output Power: 38.731 VA
Battery Current: -0.050 A
Battery Voltage: 13.170 V
Battery Power: -0.659 W
Battery Charge: 100.000 %
The web UI also includes a Remote Panel Control section for:
- Remote Panel Mode (
on,off,charger_only,inverter_only) - Remote Panel Current Limit (AC input current limit in amps)
- Remote Panel Standby (prevent sleep while turned off)
The combined mode + current limit action maps to the same behavior as
set_remote_panel_state in victron-mk3.
The backing HTTP API endpoints are:
GET/POST /api/remote-panel/stateGET/POST /api/remote-panel/standby
Munin
The Munin plugin location is at /munin (http://localhost:8080/munin).
Example output:
multigraph in_batvolt
volt.value 13.154
multigraph in_batcharge
charge.value 100.000
multigraph in_batcurrent
current.value -0.092
multigraph in_batpower
power.value -1.209
multigraph in_mainscurrent
currentin.value 1.860
currentout.value 1.676
multigraph in_mainsvoltage
voltagein.value 225.786
voltageout.value 225.786
multigraph in_mainspower
powerin.value 419.945
powerout.value 378.372
multigraph in_mainsfreq
freqin.value 50.361
freqout.value 50.026
Prometheus
The Prometheus endpoint is at the default /metrics path (http://localhost:8080/metrics).
Sample Prometheus yaml entry:
- job_name: "victron"
static_configs:
- targets: ["localhost:8080"]
The metrics that are tracked:
# HELP battery_charge_percentage Remaining battery charge.
# TYPE battery_charge_percentage gauge
battery_charge_percentage 100
# HELP battery_current_a Battery current.
# TYPE battery_current_a gauge
battery_current_a -0.06
# HELP battery_power_w Battery power.
# TYPE battery_power_w gauge
battery_power_w -0.7896
# HELP battery_voltage_v Voltage of the battery.
# TYPE battery_voltage_v gauge
battery_voltage_v 13.16
# HELP go_gc_duration_seconds A summary of the GC invocation durations.
# TYPE go_gc_duration_seconds summary
go_gc_duration_seconds{quantile="0"} 5.3183e-05
go_gc_duration_seconds{quantile="0.25"} 0.000116
go_gc_duration_seconds{quantile="0.5"} 0.000156305
go_gc_duration_seconds{quantile="0.75"} 0.000313721
go_gc_duration_seconds{quantile="1"} 0.044886879
go_gc_duration_seconds_sum 0.394171418
go_gc_duration_seconds_count 58
# HELP go_goroutines Number of goroutines that currently exist.
# TYPE go_goroutines gauge
go_goroutines 8
# HELP go_info Information about the Go environment.
# TYPE go_info gauge
go_info{version="go1.11.3"} 1
# HELP go_memstats_alloc_bytes Number of bytes allocated and still in use.
# TYPE go_memstats_alloc_bytes gauge
go_memstats_alloc_bytes 3.21496e+06
# HELP go_memstats_alloc_bytes_total Total number of bytes allocated, even if freed.
# TYPE go_memstats_alloc_bytes_total counter
go_memstats_alloc_bytes_total 1.7361072e+08
# HELP go_memstats_buck_hash_sys_bytes Number of bytes used by the profiling bucket hash table.
# TYPE go_memstats_buck_hash_sys_bytes gauge
go_memstats_buck_hash_sys_bytes 1.451092e+06
# HELP go_memstats_frees_total Total number of frees.
# TYPE go_memstats_frees_total counter
go_memstats_frees_total 263807
# HELP go_memstats_gc_cpu_fraction The fraction of this program's available CPU time used by the GC since the program started.
# TYPE go_memstats_gc_cpu_fraction gauge
go_memstats_gc_cpu_fraction 0.00018297252897512647
# HELP go_memstats_gc_sys_bytes Number of bytes used for garbage collection system metadata.
# TYPE go_memstats_gc_sys_bytes gauge
go_memstats_gc_sys_bytes 2.37568e+06
# HELP go_memstats_heap_alloc_bytes Number of heap bytes allocated and still in use.
# TYPE go_memstats_heap_alloc_bytes gauge
go_memstats_heap_alloc_bytes 3.21496e+06
# HELP go_memstats_heap_idle_bytes Number of heap bytes waiting to be used.
# TYPE go_memstats_heap_idle_bytes gauge
go_memstats_heap_idle_bytes 6.2537728e+07
# HELP go_memstats_heap_inuse_bytes Number of heap bytes that are in use.
# TYPE go_memstats_heap_inuse_bytes gauge
go_memstats_heap_inuse_bytes 3.981312e+06
# HELP go_memstats_heap_objects Number of allocated objects.
# TYPE go_memstats_heap_objects gauge
go_memstats_heap_objects 5588
# HELP go_memstats_heap_released_bytes Number of heap bytes released to OS.
# TYPE go_memstats_heap_released_bytes gauge
go_memstats_heap_released_bytes 0
# HELP go_memstats_heap_sys_bytes Number of heap bytes obtained from system.
# TYPE go_memstats_heap_sys_bytes gauge
go_memstats_heap_sys_bytes 6.651904e+07
# HELP go_memstats_last_gc_time_seconds Number of seconds since 1970 of last garbage collection.
# TYPE go_memstats_last_gc_time_seconds gauge
go_memstats_last_gc_time_seconds 1.5450709952576678e+09
# HELP go_memstats_lookups_total Total number of pointer lookups.
# TYPE go_memstats_lookups_total counter
go_memstats_lookups_total 0
# HELP go_memstats_mallocs_total Total number of mallocs.
# TYPE go_memstats_mallocs_total counter
go_memstats_mallocs_total 269395
# HELP go_memstats_mcache_inuse_bytes Number of bytes in use by mcache structures.
# TYPE go_memstats_mcache_inuse_bytes gauge
go_memstats_mcache_inuse_bytes 3456
# HELP go_memstats_mcache_sys_bytes Number of bytes used for mcache structures obtained from system.
# TYPE go_memstats_mcache_sys_bytes gauge
go_memstats_mcache_sys_bytes 16384
# HELP go_memstats_mspan_inuse_bytes Number of bytes in use by mspan structures.
# TYPE go_memstats_mspan_inuse_bytes gauge
go_memstats_mspan_inuse_bytes 27208
# HELP go_memstats_mspan_sys_bytes Number of bytes used for mspan structures obtained from system.
# TYPE go_memstats_mspan_sys_bytes gauge
go_memstats_mspan_sys_bytes 32768
# HELP go_memstats_next_gc_bytes Number of heap bytes when next garbage collection will take place.
# TYPE go_memstats_next_gc_bytes gauge
go_memstats_next_gc_bytes 4.194304e+06
# HELP go_memstats_other_sys_bytes Number of bytes used for other system allocations.
# TYPE go_memstats_other_sys_bytes gauge
go_memstats_other_sys_bytes 775332
# HELP go_memstats_stack_inuse_bytes Number of bytes in use by the stack allocator.
# TYPE go_memstats_stack_inuse_bytes gauge
go_memstats_stack_inuse_bytes 589824
# HELP go_memstats_stack_sys_bytes Number of bytes obtained from system for stack allocator.
# TYPE go_memstats_stack_sys_bytes gauge
go_memstats_stack_sys_bytes 589824
# HELP go_memstats_sys_bytes Number of bytes obtained from system.
# TYPE go_memstats_sys_bytes gauge
go_memstats_sys_bytes 7.176012e+07
# HELP go_threads Number of OS threads created.
# TYPE go_threads gauge
go_threads 10
# HELP mains_current_in_a Mains current flowing into inverter
# TYPE mains_current_in_a gauge
mains_current_in_a 2.17
# HELP mains_current_out_a Mains current flowing out of inverter
# TYPE mains_current_out_a gauge
mains_current_out_a 2
# HELP mains_freq_in_hz Mains frequency at inverter input
# TYPE mains_freq_in_hz gauge
mains_freq_in_hz 50.36082474226804
# HELP mains_freq_out_hz Mains frequency at inverter output
# TYPE mains_freq_out_hz gauge
mains_freq_out_hz 50.153452685421996
# HELP mains_power_in_va Mains power in
# TYPE mains_power_in_va gauge
mains_power_in_va 491.6352
# HELP mains_power_out_va Mains power out
# TYPE mains_power_out_va gauge
mains_power_out_va 453.12
# HELP mains_voltage_in_v Mains voltage at input of inverter
# TYPE mains_voltage_in_v gauge
mains_voltage_in_v 226.56
# HELP mains_voltage_out_v Mains voltage at output of inverter
# TYPE mains_voltage_out_v gauge
mains_voltage_out_v 226.56
# HELP process_cpu_seconds_total Total user and system CPU time spent in seconds.
# TYPE process_cpu_seconds_total counter
process_cpu_seconds_total 39.73
# HELP process_max_fds Maximum number of open file descriptors.
# TYPE process_max_fds gauge
process_max_fds 1.048576e+06
# HELP process_open_fds Number of open file descriptors.
# TYPE process_open_fds gauge
process_open_fds 8
# HELP process_resident_memory_bytes Resident memory size in bytes.
# TYPE process_resident_memory_bytes gauge
process_resident_memory_bytes 1.2742656e+07
# HELP process_start_time_seconds Start time of the process since unix epoch in seconds.
# TYPE process_start_time_seconds gauge
process_start_time_seconds 1.54506833485e+09
# HELP process_virtual_memory_bytes Virtual memory size in bytes.
# TYPE process_virtual_memory_bytes gauge
process_virtual_memory_bytes 1.15101696e+08
MQTT
The MQTT client will publish updates to the given broker at the set topic.
MQTT Configuration Options
--mqtt.enabled Enable MQTT publishing. [$MQTT_ENABLED]
--mqtt.broker= Set the host port and scheme of the MQTT broker. (default: tcp://localhost:1883) [$MQTT_BROKER]
--mqtt.client_id= Set the client ID for the MQTT connection. (default: inverter-gui) [$MQTT_CLIENT_ID]
--mqtt.topic= Set the MQTT topic updates published to. (default: invertergui/updates) [$MQTT_TOPIC]
--mqtt.command_topic= Set the MQTT topic that receives write commands for Victron settings/RAM variables. (default: invertergui/settings/set) [$MQTT_COMMAND_TOPIC]
--mqtt.status_topic= Set the MQTT topic where write command status updates are published. (default: invertergui/settings/status) [$MQTT_STATUS_TOPIC]
--mqtt.device_id= Set logical device ID used for per-device orchestration topics. (default: invertergui) [$MQTT_DEVICE_ID]
--mqtt.history_size= Number of samples retained for rolling history summaries. (default: 120) [$MQTT_HISTORY_SIZE]
--mqtt.ha.enabled Enable Home Assistant MQTT discovery integration. [$MQTT_HA_ENABLED]
--mqtt.ha.discovery_prefix= Set Home Assistant MQTT discovery prefix. (default: homeassistant) [$MQTT_HA_DISCOVERY_PREFIX]
--mqtt.ha.node_id= Set Home Assistant node ID used for discovery topics and unique IDs. (default: invertergui) [$MQTT_HA_NODE_ID]
--mqtt.ha.device_name= Set Home Assistant device display name. (default: Victron Inverter) [$MQTT_HA_DEVICE_NAME]
--mqtt.venus.enabled Enable Venus-style MQTT compatibility topics (N/W model). [$MQTT_VENUS_ENABLED]
--mqtt.venus.portal_id= Set Venus portal ID segment used in N/W topics. (default: invertergui) [$MQTT_VENUS_PORTAL_ID]
--mqtt.venus.service= Set Venus service segment used in N/W topics. (default: vebus/257) [$MQTT_VENUS_SERVICE]
--mqtt.venus.subscribe_writes Subscribe to Venus W/... topics and map to MK2 commands. [$MQTT_VENUS_SUBSCRIBE_WRITES]
--mqtt.username= Set the MQTT username [$MQTT_USERNAME]
--mqtt.password= Set the MQTT password [$MQTT_PASSWORD]
--mqtt.password-file= Path to a file containing the MQTT password [$MQTT_PASSWORD_FILE]
Related global option:
--read_only Disable all write operations and run in monitoring-only mode. [$READ_ONLY]
The MQTT client can be enabled by setting the environment variable MQTT_ENABLED=true or flag --mqtt.enabled.
All MQTT configuration can be done via flags or as environment variables.
The URI for the broker can be configured format should be scheme://host:port, where "scheme" is one of "tcp", "ssl", or "ws".
When --mqtt.command_topic is configured, the application subscribes to that topic and accepts JSON write commands.
The recommended command for inverter control follows the same model used by victron-mk3:
{
"request_id": "optional-correlation-id",
"kind": "panel_state",
"switch": "on",
"current_limit": 16.5
}
switch supports charger_only, inverter_only, on, and off (or numeric values 1..4).
current_limit is in amps and optional. If omitted, only the switch state is changed.
To update only the current limit (while preserving the last known mode), send:
{
"kind": "panel_state",
"current_limit": 12.0
}
If no prior mode is known (for example on a fresh broker state), this command is rejected until a mode command is sent once.
Standby can be controlled with:
{
"kind": "standby",
"standby": true
}
Low-level writes are still supported:
{
"kind": "setting",
"id": 15,
"value": 1
}
kind supports panel_state, setting, and ram_var (with aliases for each).
The result is published to --mqtt.status_topic with status ok or error.
MQTT Device Orchestration Topics
For multi-device deployments on one MQTT broker, invertergui now also publishes
device-scoped orchestration topics under:
{topic-root}/devices/{device_id}/state{topic-root}/devices/{device_id}/history/summary{topic-root}/devices/{device_id}/alarms/active
Set --mqtt.device_id (or MQTT_DEVICE_ID) per inverter instance so each instance
publishes to a unique device path.
Rolling history depth for the summary window is set by --mqtt.history_size.
Venus-Style MQTT Compatibility
Enable Venus-compatible topics with:
--mqtt.venus.enabled
When enabled, invertergui publishes Venus-style notifications to:
N/{portal_id}/{service}/...
Defaults:
portal_id:invertergui(--mqtt.venus.portal_id)service:vebus/257(--mqtt.venus.service)
Published paths include common VE.Bus style values such as:
Dc/0/Voltage,Dc/0/Current,Dc/0/Power,SocAc/ActiveIn/L1/V,Ac/ActiveIn/L1/I,Ac/ActiveIn/L1/F,Ac/ActiveIn/L1/PAc/Out/L1/V,Ac/Out/L1/I,Ac/Out/L1/F,Ac/Out/L1/P- alarm paths (
Alarms/LowBattery,Alarms/HighTemperature,Alarms/Overload,Alarms/Communication)
Optional write compatibility can be enabled with:
--mqtt.venus.subscribe_writes
This subscribes to:
W/{portal_id}/{service}/#
and maps supported write paths to MK2 control operations:
Mode-> remote panel modeAc/ActiveIn/CurrentLimit-> remote panel current limitSettings/Standby/RemotePanel/Standby-> standby control
Home Assistant
Enable Home Assistant auto-discovery with:
--mqtt.ha.enabled
When enabled, invertergui publishes retained discovery payloads and availability under:
{topic-root}/homeassistant/availability(online/offline){discovery_prefix}/sensor/{node_id}/.../config{discovery_prefix}/binary_sensor/{node_id}/.../config{discovery_prefix}/select/{node_id}/remote_panel_mode/config(if command topic is configured){discovery_prefix}/number/{node_id}/remote_panel_current_limit/config(if command topic is configured){discovery_prefix}/switch/{node_id}/remote_panel_standby/config(if command topic is configured)
The discovered entities include battery/input/output sensors, a data-valid diagnostic binary sensor, plus remote panel controls for:
Remote Panel Mode(on,off,charger_only,inverter_only)Remote Panel Current Limit(AC input current limit in amps)Remote Panel Standby(prevent device sleep while off)
The combined mode + current limit behavior is provided through the panel_state MQTT command kind,
which mirrors victron_mk3.set_remote_panel_state.
Home Assistant Custom Component (MQTT)
This repository also includes a custom Home Assistant integration at:
custom_components/victron_mk2_mqtt
This component is useful if you want HA entities/services that are explicitly tied to
invertergui MQTT topics, instead of relying only on MQTT auto-discovery entities.
If you use this custom component, you can disable --mqtt.ha.enabled in invertergui
to avoid duplicate entities created by MQTT discovery.
Install via HACS:
- Add the integration repository in Home Assistant:
- Install
Victron MK2 MQTTfrom HACS. - Restart Home Assistant.
- Add the YAML configuration shown below.
If you are not mirroring this repo to GitHub, use the manual install method below.
Manual install (alternative):
<home-assistant-config>/custom_components/victron_mk2_mqtt
Then add YAML config:
victron_mk2_mqtt:
name: Victron Inverter
state_topic: invertergui/updates
command_topic: invertergui/settings/set
status_topic: invertergui/settings/status
# topic_root is optional; defaults to state_topic root (for example "invertergui")
# topic_root: invertergui
Provided entities include:
- Telemetry sensors (battery/input/output voltage/current/frequency and derived power)
Remote Panel Mode(charger_only,inverter_only,on,off)Remote Panel Current Limit(A)Remote Panel Standby- Diagnostic entities (
Data Valid,Last Command Error)
Service exposed by the integration:
victron_mk2_mqtt.set_remote_panel_state
Example service call:
service: victron_mk2_mqtt.set_remote_panel_state
data:
mode: on
current_limit: 16.0
Home Assistant MQTT-Only Dashboard (No Duplicate Entities)
If you want the same control/telemetry experience but only via MQTT (without duplicate entities from discovery/custom integrations), use the packaged Home Assistant files:
- MQTT entity + control package:
homeassistant/packages/invertergui_mqtt.yaml - Lovelace dashboard:
homeassistant/dashboards/invertergui_mqtt_dashboard.yaml
The package assumes default topics (invertergui/updates, invertergui/settings/set,
invertergui/settings/status). If you use custom MQTT topics, update those values in
homeassistant/packages/invertergui_mqtt.yaml.
Recommended for this mode:
- Disable MQTT discovery output from
invertergui(--mqtt.ha.enabled=false) - Do not enable the
victron_mk2_mqttcustom component at the same time
- Ensure HA packages are enabled (if not already):
homeassistant:
packages: !include_dir_named packages
- Copy package file to your HA config:
<home-assistant-config>/packages/invertergui_mqtt.yaml
- Copy dashboard file to your HA config:
<home-assistant-config>/dashboards/invertergui_mqtt_dashboard.yaml
- Register the dashboard (YAML mode example):
lovelace:
mode: storage
dashboards:
invertergui-victron:
mode: yaml
title: Victron MQTT
icon: mdi:flash
show_in_sidebar: true
filename: dashboards/invertergui_mqtt_dashboard.yaml
- Restart Home Assistant.
TTY Device
The intertergui application makes use of a serial tty device to monitor the Multiplus.
Example
-dev=/dev/ttyUSB0
Nginx Proxy
The following configuration works for Nginx to allow the invertergui to be proxied.
When using a stand HTTP or HTTPS port to expose the gui:
location /invertergui {
return 302 /invertergui/;
}
location /invertergui/ {
proxy_pass http://localhost:8080/;
proxy_set_header Host $host;
}
location /invertergui/ws {
proxy_pass http://localhost:8080/ws;
proxy_http_version 1.1;
proxy_set_header Upgrade $http_upgrade;
proxy_set_header Connection "upgrade";
proxy_read_timeout 86400;
proxy_set_header Host $host;
proxy_set_header Referer $http_referer;
proxy_set_header X-Forwarded-For $remote_addr;
proxy_set_header X-Forwarded-Proto $scheme;
proxy_set_header X-Forwarded-Port $server_port;
}
When using a non-stand HTTP or HTTPS port to expose the gui change the HTTP Host description:
proxy_set_header Host $host:$server_port;
The last four lines are optional, but is useful when debugging and logging connections:
proxy_set_header Referer $http_referer;
proxy_set_header X-Forwarded-For $remote_addr;
proxy_set_header X-Forwarded-Proto $scheme;
proxy_set_header X-Forwarded-Port $server_port;
Grafana
This repos includes a Grafana dashboard in the grafana folder that you can import. This is useful if you are using prometheus to log your data and want to display it in a nice way.